Filter Results By:

Products

Applications

Manufacturers

Single Phase

A single alternating voltage.


Showing results: 256 - 270 of 278 items found.

  • IQ Mixers

    Fairview Microwave Inc.

    The new MMIC IQ mixers from Fairview (also known as IQ modulators) utilize a highly reliable GaAs MESFET semiconductor process which integrates a pair of matched double balanced mixer cells, a 90-degree hybrid and a 0-degree splitter/combiner that produces exceptional amplitude and phase balance performance. This level of integration offers size and performance advantages in comparison to discrete module assemblies. With the addition of an external 90-degree IF hybrid module, these IQ mixers can be used as either a Single Sideband Up-converter Mixer or an Image Reject Down-converter Mixer. The benefit of image rejection and sideband suppression can reduce overall system cost and complexity by removing the need for pre-selection filtering. Typical applications include point-to-point and point-to-multipoint radio, VSAT, military radar, electronic warfare, satellite communications, test equipment, and sensors.

  • Regulators

    Parker Hannifin Corp.

    Parker offers a range of air-line, pressure high flow and single phase regulators for instrumentation, filtration, refrigeration and pneumatic applications. Instrumentation regulators are used in the process, power, oil, gas and semiconductor industries to control the flow of liquids and gases with speed and precision. Air regulators provide quick response and accurate pressure regulation for the most demanding industrial air preparation applications, available as miniature, economy, compact, standard, hi-flow and pilot-operated regulators to meet a variety of service needs. The refrigeration line of pressure regulators includes valves that control inlet, outlet or differential pressure. Each regulator is available with an assortment of variations which enable one regulator to perform multiple functions. All regulators are built to the highest quality standards, recognized around the world for their performance, durability and reliability.

  • Three-Phase Transformer Winding Resistance Meters

    TWA Standard Series - IBEKO Power AB

    When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.

  • Three-Phase Transformer Winding Resistance Meters

    TWA Advanced Series - IBEKO Power AB

    TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.

  • Primary Current Injection Sets

    R.R.Transformers & Equipments

    Protective devices such as relays, overload Coils, Circuit breakers and CTS etc. must be checked regularly to ensure that they are always ready to operate correctly, Routine current injection testing will quickly detect faulty or incorrectly adjusted protection circuits / devices & will be possible to prevent serious damage to the system. Primary injection kit is designed to operate on single phase 230/240 volts AC 50 HZ to develop smooth & continuous test current as for loading, calibrating, and testing of CTS, Bimetal Relays, Protection Relays etc. The test set gives high current output at low cost and with inherent safety. The primary current injection testing checks all parts of the protection system by injecting current down the cable / bus bars. The application of the primary current injection sets is to ascertain the current carrying capacity of any Conductor, insulator, connector or calibration of CTS / Bi-metallic relays etc.

  • Fully Automatic Transformer Winding Resistance Tester

    Neutronics Manufacturing Co.

    Measure DC resistance of transformers windings etc. Introduction: The NMC ''TDR'' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. ''TDR'' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. ''TDR'' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.Principle: The constant current generated is fed to the resistance under test through the current terminals and the voltage drop across the resistance under test is measured and displayed in ohms. A true four terminal measurement is used to eliminate the need for lead resistance compensation.

  • Harmonic/Flicker Analyzer for IEC61000-3-2/3/11/12, IEC61000-4/7/15

    KHA3000 - Kikusui Electronics Corp.

    KHA3000, in addition to the complied standards and features of the KHA1000 (dedicated for single phase), is equipped for the harmonic and flicker compliance test exceeding 16A of the single-phase and three-phase equipment. With this unit alone, you can take highly accurate simultaneous three-phase measurements up to 40A/phase*. Furthermore, the KHA series is compliant with two measurement technique standards, the existing and the latest versions, so you can simply select to take measurements for the latest standard including interharmonics and for the conventional integral multiple harmonics without using any other device. In addition to the real-time display that can be used like an oscilloscope and FFT analyzer, the unit offers the real-time judgment of compliance with standards. Using this unit alone, you can judge test results and prepare result reports without the use of a PC. On top of that, you can easily set up a test system by combining KHA3000 with an AC power supply (PCR-LA Series) and a line impedance network (LIN40MA-PCR-L).

  • NI-9244, 400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module

    783106-01 - NI

    400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9244 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, industrial machinery, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9244 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta. You can incorporate the NI‑9244 into systems to meet standards such as IEC 61010‑1, C37.90 and C37.60, IEC 60255‑22‑(1:7), IEC 60255‑1, C37.188 Class M and P, EMC section of IEC 60870, EMC sections of IEC 61850, IEC 61000‑4‑30 Class S, and IEC 61000‑4‑7.

  • Three-Phase Transformer Demagnetizer

    DEM60C - IBEKO Power AB

    After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.

  • Portable Test Platform

    FTB-4 Pro - EXFO Inc.

    The FTB-4 Pro is the latest addition to EXFO’s test orchestration portfolio which transforms business as usual into smarter, scalable network testing that significantly increases operational efficiency and provides vital insights into field operations, network performance and service delivery. The 4 slot modular FTB-4 Pro platform enables a unique combination for 100G commissioning, turn-up and troubleshooting which includes the FTBx-88200NGE 100G Multiservice tester (with iOptics transceiver validation software) and the FTB-5240S-P optical spectrum analyzer. There is no need to carry additional platforms or swap modules for unmatched transport and spectral testing on a single platform that no one in the industry can offer. The versatile FTB-4 Pro platform supports a wide range of modules for field testing, data center interconnect, submarine testing, and lab applications for maximum flexibility and ROI across all phases of the service delivery chain: development, deployment, maintenance and troubleshooting. Module combinations on the FTB-4 Pro can also include iOLM/OTDRs, market leading OLTS for fiber characterization, dispersion solutions and other transport modules all with compatibility with EXFO’s market leading fiber inspection probes.

  • Transformer and Reactor Loss Measurement System

    Measurements International Ltd.

    The measurement of electric power and energy at high voltages and currents at low power factors is becoming increasingly important economically as a way to reduce costs in an ever-growing industrial economy. Today the transformer purchaser subjects the transformer manufacturer to an economic penalty for losses that occur in load and no-load conditions. To keep these penalties as low as possible, it is important that the manufacturer accurately measure these losses. Failure to do so can result in the manufacturer losing important contract awards to their competitors who may be utilizing a more accurate system. Using “State of the Art” proven two-stage-currentcomparator technology, the AccuLoss™ Series of transformer loss measurement systems is designed to meet the needs of today’s transformer manufacturer by providing the most accurate power loss measurement system in the world. Designed for power frequency testing and calibration, the AccuLoss™ system can be used for testing small, medium and large power transformers as well as motors and turbines up to 400 Hz. The system is also ideal for R&D facilities. The AccuLoss™ system can also be used to measure losses in single and three phase reactors.

  • Audio Test Software

    Soft Hearts LLC

    1. Distortion free stimulus even the equalized stimulus.2. Unlimited channels acquisition and processing. (Hardware limited)3. Human correlated listening test(Bark Scale intensity chart). (Requires large memory)4. Hi Res intensity chart for buzz/pop detection. (Requires large memory)5. Auto equalization method with target dBSPL accuracy.6. TCP client for test framework integration.7. Easy limits and logs development.8. Easy logs visualization module.9. Auto waveform alignment and triggering.(Upto single point alignment accuracy)10. Easy regression testing via TCP client.11. Standard Magnitude, Phase, THD, THD+N, Rubb&Buzz, Pink Noise, Noise Tests.12. Unlimited calibrations and equalization for scaling to different products and stations.13. Lowest test system and test sequence development times.14. Requires minimal training and debugging.15. Automatically avoid Reference speaker play and stop pops.16. WMD/ASIO driver compatible sound cards supported.(B&K 3670 recommended)

  • Digital Electrical Network Analyzer

    1826 NA - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.

  • 40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger

    SD750100G - Zhejiang Sandi Electric Co., Ltd

    40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger is for DC battery system charging station. With three-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. 50-500Vdc output voltage range optional, suitable for all types of batteries.FeaturesProduct Introduction:SAND AC/DC Charger is specially developed for DC chargers module. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase or single phase, DC output voltage range from 100 to 750VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger module.Unique function:● High efficiency over the full load range, full load efficiency greater than 95.5%● Wide output voltage range, 100-750VDC, suitable for a wide range of Lithium and lead acid battery● 5-inch LCD touch screen, easy to operate● Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operateMain features:● Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.● Three phase active power factor correction technology, reduces the harmonic interference to the grid● Dual DSP design, achieve the full digital control, less components means high reliability● Wide input voltage range, allows operation in most poor grid conditions● Soft start charging and soft shutdown minimize the impact on the battery.● Input, output have protective circuit breaker switch● Module adopts hot pluggable design, which is convenient for maintenance.● CAN/RS485 interface (Optional)SpecificationModel SD750100GAC input Input system Three phases + PEVoltage range 280Vac ~500VacRated voltage 440VacFrequency range 50Hz/60HzMaximum current <74AITHD (total harmonic distortion) <5%DC output Output power 40KWVoltage range 50-750Vdc ( can set)Constant power output voltage range 400Vdc-750VdcOutput current range (A) 100A ( 1~100A can set)Output current limit 1-100A continuously adjustableSteady voltage precision <±0.5%Steady current precision ≤±1% (rated range of 20% ~ 100% for output load)Load regulation rate ≤±0.5%Startup overshoot ≤±3%Peak-to-peak value noise ≤1% (200~1000V, 0~20MHz)Display Indication Light Green LED: normal operation,Yellow LED: alarm, Red LED: failureDisplay language EnglishDisplay 5’ LCD touch screenPower factor and THD Power factor ≥0.90 Full-load output power of @20%~50%≥0.98 Full-load output power of @50%~100%≥0.99 Full-load output power, input nominal voltage and frequency of @100%THD ≤5% Full-load output power of @50%~100%Protection function input overvoltage Protection Over Under Voltage automatic shutdown and restart when voltage return normalOutput overvoltage protection Over Under Voltage automatic shutdown and restart when voltage return normalOver-temperature protection Automatic shutdown. Automatic restart when the temperature return to normalShort circuit protection Automatic shutdown and lock, need power off to restart to unlockEfficiency Under Rated input voltage ≥95.2%

  • Turns Ratio Testers

    TRT Standard Series - IBEKO Power AB

    When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.

Get Help